Heading CD Description Unit General EU EFTA SADC
85.35 Electrical apparatus for switching or protecting electrical circuits, or for making connections to or in electrical circuits (for example, switches, fuses, lightning arresters, voltage limiters, surge suppressors, plugs and other connectors, junction boxes), for a voltage exceeding 1 000V:
8535.10 6 - Fuses kg 5% free free free
8535.2 - Automatic circuit breakers:
8535.21 -- For a voltage of less than 72,5kV:
8535.21.05 8 --- With moulded casings of plastics, with a current rating not exceeding 1 250 A, for a voltage not exceeding 1,1 kV (AC) or 125 V per pole (DC) and a breaking capacity rating not exceeding 100 000 A kg 15% free free free
8535.21.10 4 --- With a current rating not exceeding 2 000 A, for a voltage exceeding 2 kV (AC) but not exceeding 12 kV (AC) and a breaking capacity exceeding 10 000 A but not exceeding 31 500 A (excluding those with moulded casings of plastics) kg 15% free free free
8535.21.20 1 --- With a current rating not exceeding 1 200 A, for a voltage exceeding 12 kV (AC) but not exceeding 24 kV (AC) and a breaking capacity rating exceeding 10 000 A but not exceeding 25 000 A (excluding those with moulded casings of plastics) kg 15% free free free
8535.21.30 9 --- With a current rating not exceeding 1 600 A, for a voltage exceeding 24kV (AC) but not exceeding 36 kV (AC) and a breaking capacity rating exceeding 10 000 A but not exceeding 31 500 A (excluding those with moulded casings of plastics) kg 5% free free free
8535.21.40 6 --- With a current rating not exceeding 1 600 A, for a voltage exceeding 36 kV (AC) but not exceeding 72,5 kV (AC) and a breaking capacity rating exceeding 10 000 A but not exceeding 21 900 A (excluding those with moulded casings of plastics) kg 15% free free free
8535.21.90 2 --- Other kg 5% free free free
8535.29 8 -- Other kg 5% free free free
8535.30 - Isolating switches and make-and-break switches:
8535.30.05 6 -- Isolating switches, with moulded casings of plastics, with a current rating not exceeding 1 250 A, for a voltage not exceeding 1 100 V (AC) or 125 V per pole (DC) and a breaking capacity rating not exceeding 100 000 A kg 15% free free free
8535.30.90 0 -- Other kg 5% free free free
8535.40 6 - Lightning arresters, voltage limiters and surge suppressors kg 5% free free free
8535.90 - Other:
8535.90.10 3 -- Switch cover plates; apparatus connectors kg 15% free free free
8535.90.90 8 -- Other kg 5% free free free

Disclaimer: Information is provided as a free service and is for reference purposes only. It does not constitute the provision of professional advice of any kind. No responsibility for any loss caused to any person acting or refraining from action as a result of any material in this publication can be accepted by the author, copyright owner or publisher. Tariff information should be confirmed with SARS.